RDAG12-8 Manual
Hello Message
H*
Hello message
Any string of characters starting with "H" will be interpreted as this command. ("H[CR]" alone is
also acceptable.) The return from this command takes the form (without the quotes):
"=Pod aa, RDAG12-8 Rev rr Firmware Ver:x.xx ACCES I/O Products, Inc."
aa is the Pod address
rr is the hardware revision, such as "B1"
x.xx is the software revision, such as "1.00"
Example:
Read the greeting message.
SEND:
Hello?[CR]
RECEIVE:
Pod 00, RDAG12-8 Rev B1 Firmware Ver:1.00 ACCES I/O Products,
Inc.[CR]
Configure Baud Rate
(When Shipped by Acces, the Baud Rate Is Set at 9600.)
BAUD=nnn
Program the Pod with a new baud rate
This command sets the Pod to communicate at a new baud rate. The parameter passed, nnn, is
slightly unusual. Each n is the same digit from the following table:
Code
Baud Rate
0
1200
1
2400
2
4800
3
9600
4
14400
5
19200
6
28800
7
57600
Therefore, valid values for the command's "nnn" are 000, 111, 222, 333, 444, 555, 666, or 777.
The Pod returns a message indicating it will comply. The message is sent in the old baud rate, not
the new one. Once the message is transmitted, the Pod changes to the new baud rate. The new baud
rate is stored in EEPROM and will be used even after power-reset, until the next "BAUD=nnn"
command is issued.
Example:
Set the Pod to 19200 baud.
SEND:
BAUD=555[CR]
Page 3-8
Manual MRDAG12-8H.Bc2
Содержание E-RDAG12-8
Страница 11: ...RDAG12 8 Manual Figure 1 1 RDAG12 8 Block Diagram Page 1 6 Manual MRDAG12 8H Bc2 ...
Страница 12: ...Figure 1 2 RDAG12 8 Hole Spacing Diagram Page 1 7 Manual MRDAG12 8H Bc2 ...
Страница 21: ...Figure 2 1 Simplified Schematic for Voltage and Current Sink Outputs Page 2 9 Manual MRDAG12 8H Bc2 ...
Страница 35: ...RDAG12 8 Manual Page A 4 Manual MRDAG12 8H Bc2 ...