Write a zero to bit 2 (set output to +5V or user pull-up).
SEND:
O2-[CR]
or
SEND:
O02-[CR]
RECEIVE:
[CR]
Write zeros to bits 0-7.
SEND:
O00[CR]
RECEIVE:
[CR]
Write zeros to every odd bit.
SEND:
OAA[CR]
RECEIVE:
[CR]
Read Firmware Revision Number
V:
Read the firmware revision number
This command is used to read the version of firmware installed in the Pod. It returns "X.XX[CR]".
Example:
Read the RDAG12-8 version number.
SEND:
V[CR]
RECEIVE:
1.00[CR]
Note
The "H" command returns the version number along with other information. See "Hello Message"
following.
Resend Last Response
n
Resend last response
This command will cause the Pod to return the same thing it just sent. This command works for all
responses less than 255 characters in length. Normally this command is used if the host detected a
parity or other line fault while receiving data, and needs the data to be sent a second time.
The "n" command may be repeated.
Example:
Assuming the last command was "I", ask Pod to resend last response.
SEND:
n
RECEIVE:
FF[CR]
;or whatever the data was
Page 3-7