04 RAMP WITH DC BRAKE: When a stop command is given, the drive will decelerate
the motor down to 0 .2 Hz (at the rate set by Parameter 20 - DECELERATION TIME)
and then activate DC braking according to the settings of Parameters 21 - DC BRAKE
TIME and 22 - DC BRAKE VOLTAGE . This is used to bring the load to a final stop,
as the motor may still be turning slightly after the drive stops .
P05
STANDARD SPEED SOURCE
P05 selects the speed reference source when the drive is in STANDARD speed mode .
The following speed references can be selected:
01 KEYPAD: Use the
and
buttons to scroll to the desired speed .
02 PRESET SPEED #1: Drive will operate at the frequency set in Parameter 31 .
03 0-10 VDC: Drive will respond to a 0-10 VDC signal wired to TB-5 (+) and TB-2 (-) .
04 4-20 mA: Drive will respond to a 4-20 mA signal wired to TB-25 (+) and TB-2 (-) .
P06
RELAY OUTPUT
P06 selects the status indication for the normally open relay output at TB-16 and TB-17:
01 NONE: Disables the relay output .
02 RUN: Closes upon a START command . Opens if the drive is in a STOP state, the
drive faults, or input power is removed . DC braking is considered a STOP state .
03 FAULT: Closes if there is no fault condition . Opens if the drive faults, or input power
is removed .
04 INVERSE FAULT: Closes if the drive faults . Opens if there is no fault condition .
05 FAULT LOCKOUT: Closes when input power is applied . Opens if three restart attempts
are unsuccessful, or if input power is removed .
06 AT SET SPEED: Closes if the drive is 0 .5 Hz of the speed setpoint .
07 ABOVE PRESET SPEED #3: Closes if the output frequency exceeds PRESET
SPEED #3 (Parameter 33) . Opens if the output frequency is equal to or less than
PRESET SPEED #3 .
08 CURRENT LIMIT: Closes if the output current exceeds the CURRENT LIMIT setting .
Opens if the output current is equal to or less than CURRENT LIMIT (see Parameter
25) .
09 AUTOMATIC SPEED MODE: Closes if an AUTOMATIC (terminal strip) speed
reference is active . Opens if a STANDARD (Parameter 5) speed reference is
active .
10 REVERSE: Closes when reverse rotation is active . Opens when forward rotation is
active (see Parameter 17 - ROTATION DIRECTION) .
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]