– 28 –
– 29 –
Always test the functioning of the smoke alarm after installation. Additionally,
a regular inspection is recommended. Ensure your hearing is protected by
maintaining an arm’s length distance between yourself and the device!
Audible and visual signals
Low battery
Whenever the battery falls below a certain voltage level, the alarm will sound a
warning signal (every 40 seconds). Whenever the warning signal sounds the alarm
must be immediately replaced with a new one! The alarm has a built-in battery
that cannot be replaced!
From the moment of the first battery warning, the alarm will still operate
at full capability for at least another 30 days!
Self-test with automatic error message
The smoke alarm will perform a periodic self-test and it is able to recalibrate the
sensitivity of the smoke measure chamber automatically in case of contamina-
tion.If the alarm’s sensitivity trigger fails under the minimum required threshold
level (e.g. due to excessive contamination of the smoke measure chamber), the unit
will beep once every 40 seconds.
If the error message does not clear upon cleaning of the alarm, then
the alarm should be immediately replaced (see chapter entitled ‘Care
and maintenance’)!
Display and functions
Mode
Audible
Visual
Note
Normal operating
mode
-
LED flashes
every 40 seconds
alarm functioning
Low battery
beep approx.
every 40 seconds
LED flashes
every 40 seconds
Replace alarm
Electronic test
beep 1x per second
(3x), pause of 1,5
seconds
LED flashes at
the same time as
alarm sounds
Alarm mute
function
-
LED flashes every
8 seconds
Mute function for
5-15 minutes
Alarm mode
beep 1x per second
(3x), pause of 1,5
seconds
LED flashes at
the same time as
alarm sounds
See chapter:
“Emergency proce-
dure when alarm
sounds”
Sensor fault
warning
beep approx.
every 40 seconds
LED flashes
every 40 seconds
Sensor is not func-
tioning properly,
replace device
Buzzer fault
warning
-
LED flashes 2x
every 40 seconds
Buzzer is not func-
tioning properly,
replace device
Audible and visual signals
Alarm mode
Upon detection of smoke, a loud, pulsating alarm tone will sound and the LED light
will flash simultaneously at short intervals. In this case, proceed as described under
the chapter entitled ‘Emergency procedure when alarm sounds’.
Alarm mute function
Once the device is in alarm mode, the alarm sound can be deactivated for 5-15
minutes by pressing the test / stop button.
GB