If the mute function is active, the LED will flash once approximately every
8 seconds.
If, after this period, fire smoke is still detected in the smoke measuring chamber,
the acoustic alarm will sound again.
Only activate the alarm mute function when you are
absolutely sure
that you can exclude a cause of fire!
Care and maintenance
What to do in case of false alarm?
Possible causes of false alarm include: Welding and cutting, soldering and other hot
work, sawing and grinding, dust created from building work, e.g. cleaning, extreme
electromagnetic effects, changes in temperature which lead to condensation in the
alarm as well as small insects and pollen.
• If a false alarm is being caused by work close to the device, it should be
temporarily covered up or removed. Upon completion of the work, it is
imperative, however, that the device be returned to its original opera-
ting state and be checked!
Cleaning
The operation of every installed smoke alarm must be regularly checked and
kept safe through maintenance measures in accordance with German DIN 14676
application standards. This includes an inspection at least once every 12 months ±
3 months, including maintenance and checking the performance of the warning
signals. The results and measures taken should be documented accordingly.
• Dust covered alarms must be cleaned. Dust deposits in the alarm’s air vents can
be sucked up.
• Dust can be removed with a brush if required.
• The surface area can be cleaned with a slightly damp and soapy cloth.
• Take care that no liquids get into the apparatus! Do not clean device in a dishwasher!
Display and functions
Care and maintenance
• Do not use any sharp, pointed, abrasive or caustic cleaning products, chemicals
or hard brushes!
Maintenance
• The electronic components of each smoke alarm are subject to ageing.
In addition, insect screens and smoke measure chambers will inevi-
tably become contaminated over time.
• Operating life of the device: The smoke alarm must be replaced no later than
10 years + 6 months after the manufacturing date.
Disassembling
To disassemble the smoke alarm,
take a screw driver and push it into
the mounting hole. Then, turn the
smoke alarm counterclockwise to
remove it from the mounting bracket.
Warranty
ABUS products are designed and manufactured with great care and tested in
accordance with applicable regulations.
The warranty extends solely to defects that can be attributed to faulty materials or
manufacturing at the time of purchase. If it can be proved that materials or
manufacturing are faulty, the warranty provider agrees to repair or replace the
smoke alarm at their own discretion.
In such cases the warranty will end upon expiry of the original warranty period of
2 years. Any further claims are expressly excluded. The built-in or included batteries
are not covered by the warranty.
ABUS accepts no liability for defects or damage arising from external influences
(e. g. through transport, excessive force, incorrect operation), improper use, normal
wear and tear or non-observance of this manual.
When making a warranty claim, the faulty smoke alarm should be accompanied
by the original proof of purchase including purchase date and a short written
Care and maintenance