Installation and operation
1. Place the mounting plate on the
desired installation location and
mark the drilling holes through the
cover base.
2. Drill the two holes with ø 5 mm.
3. Fit the rawlplugs into the drill
holes.
4. Insert the screws into the mounting
socket.
5. Attach smoke alarm by turning
clockwise at the detector base.
When marking out your
drill holes, ensure that no
electrical wires / cables,
pipes or other installation
components are located
behind the installation
point!
Installation and operation
Ceiling
Plugs
Mounting socket
Screws
Smoke alarm
Setting up
• As soon as the smoke alarm is fixed to the mounting socket, the battery connec-
tions will automatically link and the unit will be powered up and ready to use.
• Whenever the smoke alarm is detached from the mounting socket, the battery
power will automatically be switched off in order to prevent unwanted sounding
of the alarm.
Normal operating mode
The LED light under the cover will flash approx. every 40 seconds in normal
operating mode signalling that the alarm is ready for use.
This smoke alarm device has an automatic night mode. In dark rooms, the LED
signal will be dimmed to prevent disturbance of the night's sleep.
Electronic test
Perform regular functional tests on your smoke alarm by holding down the test /
stop button (for approx. 3 seconds). The warning tone will sound and the ‘ALARM’
LED light will flash. This does not signal that there is smoke in the room but it is
confirmation that the smoke alarm is functioning correctly.
Installation and operation
Test / stop button
GB