38
Step 3:
Wiring RJ45 cable from
ESS-INV
to
ESS-MET
for RS485 communication.
1. Make a RJ45 cable and wiring from ESS-INV to the terminals of RS485-1.
2. Pin8 as Data+/A, Pin7 as Data-/B.
3. There are two RJ45 port on the ESS-INV can be use, each port is connect in parallel inside so just
select one port for communication with ESS-MET and the other one is use for ESS-INV parallel
requirement.
4. The terminals of RS485-2 is reserved for slave mode which provide the function to monitor the
system by external devices.