12
2.1.1Enter into Setting Mode
Make sure the output voltage and capacity of the battery are set properly.
Caution!
Before entering into setting mode, make sure the battery and the load are removed;
otherwise, it might damage the battery and the load due to improper setting.
Step1: Make sure the charger is connected with solar cell with 40V~150Vdc voltage and
do not turn on the charge.
Step2: Press
and
simultaneously, then turn on the charger. You may see
the three LEDs on the front panel will light up and extinguish after 3 second. Then,
“AH” text will be indicated on the LCD display, which means the charger is in
setting mode now. If no “AH” text shown on the LCD, you need to repeat Step 2.
Step3: Press
or
to choose item to be set. Basically, you may set Battery
Capacity(AH), Battery Voltage(BATT), Battery High Limit (BAUP), Battery Low
Limit(BADW), Pulse Mode Setting(PULS), ID(ID), and total input power(KWH).
Press
to go to the desired item.
Display
Description
Battery Capacity Setting
Battery Voltage Setting
Battery Over-voltage
Setting
Battery Under-voltage
Setting
Pulse Charge Setting
Parallel Address Setting
Total Input Power(KWH)
Setting
Содержание Buck 1000W
Страница 1: ...Photovoltaic Charger User s Manual Buck 1000W 1500W 12 24 36 48 Vdc...
Страница 22: ...22...
Страница 23: ...23...
Страница 24: ...24 192321452000000...