36
Periodic Testing / Maintenance
It is highly recommended that you preform a full System
Check (see page 33) at least twice a month. This will
confi rm that the Pendant battery is in good condition
and that the Base unit is able to get a dial tone.
Replacing Batteries
Replace the Base unit batteries every 2 years - or as
needed. Be sure to purchase NiMH AA batteries with
2400 mAh or greater capacity. A set of batteries in
good condition and fully charged will supply 24 hours
of back-up in the event of a power outage. You can test
this by unplugging the AC Adapter and hearing the voice
prompts. When the unit is operating on the backup
batteries, it will announce “Running On Battery Power”
twice and the RED Power LED will continue to fl ash. If
power is not restored within an 8 hour period, the unit
will start to announce “Running On Battery Power” once
every 30 minutes until power is restored or the back up
batteries are depleted.
(Note that lower capacity batter-
ies can be used - but they will give less back-up time).
Out of Service Storage or Transportation
When storing, traveling or shipping the Base unit turn
the Master ON/OFF switch to OFF so that the “Running
on battery power” announcement is disabled. Remem-
ber to turn the Master ON / OFF switch to ON when it is
put back in service.
Caution - This equipment cannot call out when other equip-
ment (telephone or a computer modem, etc.) are in use on
the same phone line. In the event someone is on the tele-
phone elsewhere in the home when you activate the System
for an emergency situation you will be connected to the
person currently on the telephone line in your home.