User manual Version 1.3
ABLELink
®
Ethernet Serial Server SE5002
Copyright © 2006 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
-
18
-
Enter
2
on “
Input choice and enter (1~5):
” of COM1, the following screen shall appear; then proceed to
assign the COM port
alias
, set
baud rate
and
parity
, determine number of
data bit
and
stop bit
, and decide
on the need of
flow control
(Fig. 18)
Fig. 18. Com port setting
Enter
3
from “
Input choice and enter (1~5):
” of COM1, by default COM port serial data buffer is enabled
meaning that when TCP/IP Ethernet connection is broken, serial data collected from serial device will be
emptied on SE5002 once TCP/IP connection is resumed, the serial data will be sent through Ethernet
connection, one may disable it if one wish(Fig. 19)
Fig. 19. Com port-Enabling serial data buffer
Packet delimiter is a way of controlling the number of packets in a serial communication. It is designed to
keep packets intack. SE5002 provides two ways in parameter setting: 1. Packet delimiter timer and 2 .
Character pattern terminator . By default, packet delimiter timer is 1 ms. The range of packet delimiter timer
is 0 to 30,000 msec, as shown in Fig. 20. If “character pattern is selected, for a data stream ended with
“0x0a04”, then the entire data buffer of the serial device is transmitted.