User manual Version 1.3
ABLELink
®
Ethernet Serial Server SE5002
Copyright © 2006 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
-
44
-
Appendix C: Re-loading System Firmware
The AP (application program) firmware of SE5002 can be disabled If a wrong version is downloaded.
To disable the current version of firmware and re-load the correct one, do the followings:
1. Turn power off, open SE5002 case.
2. Short pin1 to pin2 on jumper JP1 (on the right-top corner of the main board) to disable the current AP
firmware.
3. Turn SE5002 power on.
4. Download the correct AP firmware. .
5. Open pin1 and pin2 on jumper JP1 to enable AP firmware.
6.
Close the case and continue operations.
Appendix D: Using SerialManager
D.1. SerialManager Introduction
SerialManager
, developed by ATOP, is a special tool for device management and configuration, and can
realize the daily management on various ATOP network devices for address search, device positioning,
parameter configuring, firmware downloading and so on.
D.2. Interface
The operating interface of the
SerialManager
shown as below:
Main menu
Device details
Status bar