Fig. 14. Com1 setup
Here one may configure COM1 parameters, include COM1 operation mode, port parameters, enabling or
disabling serial buffer’s data and packet delimiter.
LINK Mode Setup
Configure SE5002 as TCP server
:
(Fig. 14)
Enter
1
on “
Input choice and enter (1~5):
” to select COM1
Enter
1
on “
Input choice(1~5) and enter
:
” to select
Overview
Input local port on “
Please input local port
:
”
1.
If one want to enable IP filter
:
Input
y
on “
Do you want to enable IP filter(y/n)?
”
Input source IP on “
Please input Filter_IP
:
”
Double click “
Enter
” key
2.
If one don’t want to enable IP filter
:
Input
n
on “
Do you want to enable IP filter(y/n)?
”
Double click “
Enter
” key
Input idle time in “
Please input idle time to send TCP alive packet(4*10sec)
:
”(
2
->the sending TCP
keep-alive packet period is 2*10 sec)
Note:
1.
One may configure COM1 or COM2 parameter by choosing COM1 or COM2 Link
2.
“IP filtering function is disabled by setting FILTER_IP to “0.0.0.0”.
3.
IP filter is disabled by default
4.
If IP filter is enabled, only the source IP assigned can be connected to SE5002.