User manual Version 1.3
ABLELink
®
Ethernet Serial Server SE5002
Copyright © 2006 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
-
16
-
Fig. 15. Link Mode-TCP server setup
Enter
2
on “
Input choice(1~5) and enter
:
”(Fig. 15)
Input destination IP on “
Please input Destination IP
:
” ( for instance:
10. 0. 29. 123
)
Input destination port on “
Please input Destination port
:
”( for instance:
666
)
1. Enter
1
for Connected always
:
Double click “
Enter
” key
Input idle time in “
Please input idle time to send TCP keep-alive packet(4*10sec)
:
”(
2
->the sending
TCP keep-alive packet period is 2*10 sec)
2. Enter
2
for Triggering by received COM port data
:
Input idle time to disconnect on “
Please input idle time to disconnect( 0sec , 1~255)
:
” (
0
->disable
the function;
2
->the serial Inactivity beyond 2 sec will cause disconnect)
Input error retrying time on “
Please input waiting time for error retrying (0 minute,1~255)
:
”
(
0
->disable the function;
2
->SE5002 trying to reconnect per 2 minutes)
Double click “
Enter
” key
Input idle time on “
Please input idle time to send TCP keep-alive packet (4*10sec)
:
”(
2
-> sending
TCP keep-alive packet period will be 2*10 sec)