User manual Version 1.3
ABLELink
®
Ethernet Serial Server SE5002
Copyright © 2006 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
-
23
-
Fig. 26. Com1 setup-TCP server
Notes:
1. Default COM1 of SE5002 is 4660 (COM2 is 4661) and it is associated with the serial port COM1 or
COM2. After the application program being connected to the TCP port 4660 on the SE5002, data of ones
application program are transparent to both COM1 and SE5002.
2. The serial interface may have different port interfaces for different models.
3.3.5 Configuring SE5002 as TCP client
:
Configure SE5002 as a TCP client. For example, the destination IP is 10.0.29.11, and the destination port
is 4660 (Fig. 27)
On
destination IP, enter
“
10.0.29.11
”
On destination port, enter “
4660
”
Input idle time on “
Please input idle time to send TCP alive packet ( sec)
:
”(
4
->the sending TCP
keep-alive packet period is 4*10 sec)
1. Select
“
TCP Connect On Power-on
”
:
It keeps trying to establish TCP connection after Power on
2. Select
“
TCP Connect On Any Serial Character
”
:
Any serial character will trigger to establish TCP
connection
Input idle time to disconnect on “
Serial Inactivity Time before disconnect (0sec , 1~255)
:
” (
0
->disable
the function;
2
-> serial Inactivity beyond 2 sec will cause disconnect)
Input error retrying time on “
Waiting Time Between Re-connect Attempts (0 minute,1~255)
:
”
(
0
->disable the function;
2
->SE5002 trying to reconnect per 2 minutes)
Click on “
Save Configuration
” button to save the changes