| Error resolution and maintenance –
Identifying errors
46
Error F8
Cause
Suggested solution
A short circuit has been detected between
the pilot contact CP and the protective earth
PE.
The vehicle's communication interface is
faulty.
The wallbox automatically reinitiates the charging proce-
dure every 60 seconds.
If the error persists, check the charging cable and/or the
charging socket of the wallbox. If you detect any damage,
take the wallbox out of operation and contact the dealer
from whom you have purchased the wallbox.
If no damage is detected when checking the charging cable
and socket, the vehicle must be checked: please contact a
qualified specialist repairer.
Error F9
Description
Flash pattern
Per cycle, the red LED flashes once first, followed
by the green LED flashing three times and then
the blue LED flashing once.
Cause
Suggested solution
The current monitoring module has detected that
the charging current is exceeding the preset max-
imum current.
The wallbox automatically reinitiates the charging proce-
dure every 60 seconds. If the error persists, the wallbox
and/or the vehicle must be checked: please contact a quali-
fied specialist electrical contractor or a specialist repairer.
Error F10
Description
Flash pattern
Per cycle, the red flashes once first, followed by
the green LED flashing twice and then the green
and blue LED flashing twice.
Cause
Suggested solution
The temperature monitoring device has detect-
ed a temperature above 80° Celsius inside the
housing.
The temperature monitoring device interrupts the charging
procedure. After 10 minutes, the charging procedure is
reinitiated automatically. If the temperature inside the
housing remains at between 60° and 80° Celsius at this
time, error code
F17
(see below) is shown and the charging
current is limited to 6 A.
The charging procedure is re-initiated as soon as the tem-
perature inside the housing falls to below 60° Celsius.
If the error repeats or persists, the wallbox must be cooled
and/or shaded more effectively at the installation site.
Should the error persist, please take the wallbox out of
operation (see page 51) and contact a qualified specialist
electrical contractor to resolve the error.
Error F11
Description
Flash pattern
Per cycle, the red and green LEDs flash once first,
followed by the green and blue LEDs flashing
three times.
Содержание Wallbox eMH2