47
Testing the RCCB
x
The wallbox is defective.
x
Please contact a qualified specialist electrical contractor to have the error resolved.
x
Should the wallbox have to be replaced, please contact the dealer from whom you have purchased your wallbox.
ATTENTION
Taking the wallbox out of operation in the event of persistent malfunction
Should the wallbox keep displaying error messages, please take it out of operation (see further below) and contact a qualified
specialist electrical contractor to resolve the error.
Testing the RCCB
To ensure continuing safe operation, you must test the function of the wallbox’s internal RCCB according to locally applicable regula-
tions: For this purpose, the RCCB has a push button with which to initiate the test function.
Proceed as follows to test the mechanical functionality of the RCCB:
1
Unlock the wallbox’s side RCCB flap using the key supplied
and flip it up.
2
Locate and press the push button engraved
T
.
x
The RCCB must now trip and flip the toggle switch into the
centre position.
1
+
0
1
0
1
0
1
0
3
Now flip the pivot lever first to the
0
position and then back to
the
I
position.
4
Close the RCCB flap and lock it with the key.
DANGER
Dangerous electrical currents
Should the RCCB malfunction during testing, you must not continue to operate the wallbox under any circumstances!
x
Take the wallbox out of operation (see next section) and contact
ABL Customer Service