background image

12

The Ability system

User’s manual

partitions the user is allowed to control. Therefore, if a key is held in the
vicinity of a reader, it will be possible to control only the partitions which
the two devices have in common.

Each reader and each key can be programmed with up to 4 shortcuts. The
user or the installer can choose, for each key, which shortcut to activate
between the key or the reader shortcut.

Unlike most traditional readers (which generally carry out arm/disarm
operations only), ABy readers also manage a series of useful shortcut
commands. For example, it is possible to associate two shortcuts with the
red and blue LEDs for arm and disarm operations, and a shortcut to the
green LED for gate control, and yet another to the yellow LED for "Clear
call queue" operations.

The buzzer signals the running entry, exit and pre-arm time of the reader
partitions (refer to paragraph

 2-3-6 Signalling on the Buzzer

).

2-4-1

Signalling on the Reader LEDs

The LEDs have two distinct operating in modes:

1. If no key is present at the reader (refer to 

Table 5: Reader LEDs with

no key at reader

), the LEDs will show the current operating status of

the reader partitions.

2. If a key is present at the reader (refer to 

Table 6: Reader LEDs with

key at reader

), the LEDs will indicate (in rapid succession) the short-

cuts available for selection.

 

Nota Bene

If a key is present, all operations (arm, disarm, etc.) will apply only to the partitions
common to both the key and reader.

Table 5: 

Reader LEDs with no key at reader

LED

Red

Blue

Green

Yellow

OFF

(no light)

All the reader partitions are disarmed. 

No alarm/tamper memory on the reader partitions or system tamper memory.

ON

(Solid)

The scenario associated with 

the arming shortcut assigned to 

the red LED is active.

The scenario associated with 

the arming shortcut assigned 

to the blue LED is active.

The scenario associated with 

the arming shortcut assigned 

to the green LED is active.

The scenario associated with 

the arming shortcut assigned 

to the yellow LED is active.

Intermittent 

blinking

(ON: 2.3sec

OFF: 0.1sec)

At least one Reader-partition is 

armed.

Slow blinking

(ON: 0.5sec

OFF: 0.5sec)

The reader partitions are 

disarmed. Alarm/tamper 

memory on at least one of the 

reader partitions, or system 

tamper memory.

The scenario associated with 

the shortcut of the last key 

used at the reader is active.

Fast blinking

(ON: 0.15sec

OFF: 0.15sec)

At least one Reader-partition is 

armed. Alarm/tamper memory 

on at least one of the reader 
partitions, or system tamper 

memory.

Table 6: 

Reader LEDs with key at reader

LED

Red

Blue

Green

Yellow

OFF

(no light)

Request to arm ALL the partitions common to both the key and reader.

ON

(only one LED 

On)

Request to activate the 

reader/key shortcut 

associated with the red LED

Request to activate the 

reader/key shortcut 

associated with the blue LED

Request to activate the 

reader/key shortcut 

associated with the green LED

Request to activate the 

reader/key shortcut 

associated with the yellow 

LED

ON

(All LEDs On).

Request to activate the customized shortcut associated with the key.

Fast blinking

(ON: 0.15sec

OFF: 0.15sec

one LED only)

If the shortcut associated with 

the red LED is an arming 

operation, one of the 

partitions concerned is not-

ready-to-arm due to zones 

which are not in standby 

status.

If the shortcut associated with 

the blue LED is an arming 

operation, one of the 

partitions concerned is not-

ready-to-arm due to zones 

which are not in standby 

status.

If the shortcut associated with 

the green LED is an arming 

operation, one of the 

partitions concerned is not-

ready-to-arm due to zones 

which are not in standby 

status.

If the shortcut associated with 

the yellow LED is an arming 

operation, one of the 

partitions concerned is not-

ready-to-arm due to zones 

which are not in standby 

status.

Fast blinking

(ON: 0.15sec

OFF: 0.15sec

ALL LEDs)

If the shortcut associated with the key is an arming operation, one of the partitions concerned is not-ready-to-arm due to 

zones which are not in standby status.

Содержание 510M

Страница 1: ...USER S MANUAL ANTI INTRUSION SYSTEM...

Страница 2: ...plies only to defects in parts and workmanship relating to normal use It does not cover damage arising from improper maintenance or negligence damage caused by fire flood wind or lightning vandalism f...

Страница 3: ...Multi system access 15 2 8 Telephone and voice functions 15 2 9 Arming Scenarios 15 Chapter 3 Shortcuts 16 3 1 Keypad shortcuts 16 3 2 Shortcut with code 17 3 3 Keys and readers shortcuts 17 3 4 Shor...

Страница 4: ...4 User s manual...

Страница 5: ...s Ability control panels 510M 510B 510V 1030M 1030B 1030V Total terminals 10 30 Terminals on panel 5 10 Terminals on panel configurable as inputs 5 10 Terminals on panel configurable as Rollerblind Sh...

Страница 6: ...The installer is the person or group of persons who sets up and programs the entire security system in accordance with the purchaser s requirements and in respect of the safety laws in force As the on...

Страница 7: ...nology of the Ability 510B V and 1030B V provides users with system status information over the phone nBy readers 2 versions available nBy S wall mount and By X flush mount allow you to access and con...

Страница 8: ...tures In addition to the traditional User menu accessed by means of user code entry this system provides a series of shortcuts refer to Shortcuts in Appendix associated with keys Generally intrusion c...

Страница 9: ...will be shown in white on black background Nota Bene Case C is discernible from case B in the fact that in case B the red LED on the keypad blinks Case C is shown only if case B is not present Table 2...

Страница 10: ...tions in the events log etc C Steps back on the open menu without changing the selected item parameter etc ESC Exits the User menu without changing the selected item parameter etc ENABLE Enables optio...

Страница 11: ...f surface by means of just two screws It is also IP34 rated heavy duty and therefore suitable for outdoor use It is equipped with a buzzer and 4 LEDs F1 Red F2 Blue F3 Green F4 Yellow The Universal fl...

Страница 12: ...signed to the green LED is active The scenario associated with the arming shortcut assigned to the yellow LED is active Intermittent blinking ON 2 3sec OFF 0 1sec At least one Reader partition is arme...

Страница 13: ...User and User Main User codes can disable ordinary User codes and change their PINs However a Main User code cannot be used to disable another Main User code or change its PIN User codes can change t...

Страница 14: ...t the following actions 1 disarm the partitions common to the key and reader concerned 2 activate the respective Patrol Time for the partitions concerned 3 re arm the partitions as before when the Pat...

Страница 15: ...contact numbers via a voice dialer The installer can associate a voice message with an event each message is customizable for the user 2 9 Arming Scenarios A scenario is a configuration programmed by...

Страница 16: ...the shortcut will activate after code recogni tion The shortcut will affect the partitions common to both the key pad and code 4 Code users only when activation of the shortcut lowers sys tem security...

Страница 17: ...ortcut associated with the blue LED of the reader or of the key 3 Green LED on for 3 seconds shortcut associated with the green LED of the reader or of the key 4 Yellow LED on for 3 seconds shortcut a...

Страница 18: ...rtcuts 2 by means of access codes via the User Menu refer to paragraph 2 5 User Codes and paragraph 3 2 Shortcut with code This chapter describes the procedure via menu as described at paragraph 2 5 1...

Страница 19: ...Clear call queue Delete memory The following shortcuts activate the associated commands Shortcut n 2 Stop alarms Shortcut n 3 Clear call queue Shortcut n 4 Delete memory Method 2 Access the Alarm mana...

Страница 20: ...bed in paragraph 2 6 1 Air2 KF100 Wireless keyfobs Via Auto arm operations If a partition is associated with a timer which controls automatic arming operations it will arm when the timer switches ON a...

Страница 21: ...category of elements zones codes etc you wish to activate deactivate 2 Use keys and followed by to select the single element 3 Use to activate the selected element or to deactivate it Other shortcuts...

Страница 22: ...ils For example the details of an Arm command will show the code and keypad concerned and if you press the list of partitions involved System voltage Zone status allows you to view only the zones asso...

Страница 23: ...icates Activate Output shortcut n 5 or Deactivate Output shortcut n 6 Via Wireless keyfob Push the respective button on the keyfob and verify the outcome of the requested operation as described in par...

Страница 24: ...Keypad Settings section of the User Menu by means of a valid PIN Follow the instructions described in Method 1 4 8 Change PIN This section allows you to change your User Code PIN If your code has Main...

Страница 25: ...hortcut n 7 Method 2 Access the Overtime req section of the User Menu by means of a valid PIN Via Reader Hold a valid digital key in the vicinity of the reader and select the LED or description relati...

Страница 26: ...nnot generate alarms The system generates tamper alarms even when partitions are disarmed ARM DISARM You can enable disable the Auto arm function on each separate partition If the auto arm option is e...

Страница 27: ...example after opening the front door otherwise the system will generate an alarm Each partition can be programmed with its own Exit time EXIT TIME OR EXIT DELAY These boards can be used to increase th...

Страница 28: ...the perimeter zones of the partition can generate alarms Instant mode this operation enables the partition perimeter zones only and annuls delays In this way violation of the perimeter zones of the p...

Страница 29: ...al entity for automatic time management of programmed peripherals or elements Ability control panels provide 2 timers TIMER Transceiver equipped devices In two way wireless systems all the devices are...

Страница 30: ...enu Accesses the User Menu section View 13 Keypad sett menu Accesses the User Menu section Keypad Keypad 14 ZoneBypass menu Accesses the User Menu section Activations Zones 15 Output control Accesses...

Страница 31: ...nel Backup battery low or disconnected Low battery The control panel backup battery is running low or is not connected properly Mains failure Mains failure The primary power source 230 Vac has failed...

Страница 32: ......

Отзывы: