The Ability system

User’s manual

2-2

The Technologies

Expertise in the arena of total security and a commitment to precision and
high quality allow our R & D professionals to deliver excellence in design
technology and dependability through time.

2-2-1

EASY4U

This user-friendly tool provides an interesting array of graphic features and
functions. Ability intrusion control panels are compatible with nCode/S
keypads (equipped with 96x32 pixel graphic displays) only. The four-line
alphanumeric display screen (16 characters per line) can be edited or used
for customized user-operations. The keypad shortcuts allow time-
consuming sequences to be transformed into simple keystroke actions. In
this way, frequently-used or repetitive sequences of keystrokes can be
eliminated. The shortcuts can be used for a variety of tasks and make
operations less tedious and less error-prone.  The use of customizable
graphic-objects, which indicate the system status, helps users to
understand the current situation.

Besides accepting various commands (Arm, Disarm, etc.), the nBy reader
also allows users to manage the "shortcuts" programmed on the keypad.

2-3

nCode/S keypad

The Ability control panels manages nCode/S keypad. The keypads allow
users to manage all aspects of the security system.

The nCode/S is equipped with:

graphic display

23 keys

4  LEDs

buzzer

The keypad is the device that allows authorized code users to control the
entire system or specific partitions. However, system control can be
extended to other building occupants who do not hold a valid code. The
Ability intrusion control panel offers an array of innovative features. In
addition to the traditional User menu (accessed by means of user-code
entry), this system provides a series of shortcuts" (refer to "Shortcuts" in

Appendix) associated with keys 

. Generally,

intrusion control panels do not allow access to the system via keypad
without code entry. However, by means of the customized (personal)

shortcuts 

 to 

 , it is possible to enable building occupants to

access and operate the system without code entry.

Your installer will program the shortcuts to suit your requirements and
explain how they are used. For example, it may be useful to allow all the
building occupants to arm the system without code entry, as this operation
increases the level of system security. However, operations which lower the
level of system security should be reserved for code users only.  Under
normal circumstances, operations which increase system security can be
allowed without valid-code entry whereas, operations which lower system
security (Disarm, Delete Alarm/Tamper memory, Deactivate Alarm/Tamper
outputs) should be allowed only after valid-code entry.

Each keypad is assigned (by the installer) to the partitions it controls.

2-3-1

Display - description

The brightness and contrast of the backlit-graphic LCD (96 x 32 pixel) can
be adjusted by way of the respective options on the User Menu (refer to
paragraph

 4-7 Keypad settings

).

The first line of the display shows the date and time.

The left side of the second line shows the characters that indicate the
current status of the partitions the keypad is assigned to:

D

 = partition disarmed

A

 = partition armed in Away mode (interior and perimeter zones armed) 

S

 = partition armed in Stay mode (perimeter zones armed)

I

 =  partition armed in Instant mode (perimeter zones armed with no delay)

-

 = partition does not belong to the keypad

1 8 : 2 3   2 0 / 0 8 / 2 0 1 1
D T P I D
  N o   a l a r m s
  N o   f a u l t s

Содержание 510M

Страница 1: ...USER S MANUAL ANTI INTRUSION SYSTEM...

Страница 2: ...plies only to defects in parts and workmanship relating to normal use It does not cover damage arising from improper maintenance or negligence damage caused by fire flood wind or lightning vandalism f...

Страница 3: ...Multi system access 15 2 8 Telephone and voice functions 15 2 9 Arming Scenarios 15 Chapter 3 Shortcuts 16 3 1 Keypad shortcuts 16 3 2 Shortcut with code 17 3 3 Keys and readers shortcuts 17 3 4 Shor...

Страница 4: ...4 User s manual...

Страница 5: ...s Ability control panels 510M 510B 510V 1030M 1030B 1030V Total terminals 10 30 Terminals on panel 5 10 Terminals on panel configurable as inputs 5 10 Terminals on panel configurable as Rollerblind Sh...

Страница 6: ...The installer is the person or group of persons who sets up and programs the entire security system in accordance with the purchaser s requirements and in respect of the safety laws in force As the on...

Страница 7: ...nology of the Ability 510B V and 1030B V provides users with system status information over the phone nBy readers 2 versions available nBy S wall mount and By X flush mount allow you to access and con...

Страница 8: ...tures In addition to the traditional User menu accessed by means of user code entry this system provides a series of shortcuts refer to Shortcuts in Appendix associated with keys Generally intrusion c...

Страница 9: ...will be shown in white on black background Nota Bene Case C is discernible from case B in the fact that in case B the red LED on the keypad blinks Case C is shown only if case B is not present Table 2...

Страница 10: ...tions in the events log etc C Steps back on the open menu without changing the selected item parameter etc ESC Exits the User menu without changing the selected item parameter etc ENABLE Enables optio...

Страница 11: ...f surface by means of just two screws It is also IP34 rated heavy duty and therefore suitable for outdoor use It is equipped with a buzzer and 4 LEDs F1 Red F2 Blue F3 Green F4 Yellow The Universal fl...

Страница 12: ...signed to the green LED is active The scenario associated with the arming shortcut assigned to the yellow LED is active Intermittent blinking ON 2 3sec OFF 0 1sec At least one Reader partition is arme...

Страница 13: ...User and User Main User codes can disable ordinary User codes and change their PINs However a Main User code cannot be used to disable another Main User code or change its PIN User codes can change t...

Страница 14: ...t the following actions 1 disarm the partitions common to the key and reader concerned 2 activate the respective Patrol Time for the partitions concerned 3 re arm the partitions as before when the Pat...

Страница 15: ...contact numbers via a voice dialer The installer can associate a voice message with an event each message is customizable for the user 2 9 Arming Scenarios A scenario is a configuration programmed by...

Страница 16: ...the shortcut will activate after code recogni tion The shortcut will affect the partitions common to both the key pad and code 4 Code users only when activation of the shortcut lowers sys tem security...

Страница 17: ...ortcut associated with the blue LED of the reader or of the key 3 Green LED on for 3 seconds shortcut associated with the green LED of the reader or of the key 4 Yellow LED on for 3 seconds shortcut a...

Страница 18: ...rtcuts 2 by means of access codes via the User Menu refer to paragraph 2 5 User Codes and paragraph 3 2 Shortcut with code This chapter describes the procedure via menu as described at paragraph 2 5 1...

Страница 19: ...Clear call queue Delete memory The following shortcuts activate the associated commands Shortcut n 2 Stop alarms Shortcut n 3 Clear call queue Shortcut n 4 Delete memory Method 2 Access the Alarm mana...

Страница 20: ...bed in paragraph 2 6 1 Air2 KF100 Wireless keyfobs Via Auto arm operations If a partition is associated with a timer which controls automatic arming operations it will arm when the timer switches ON a...

Страница 21: ...category of elements zones codes etc you wish to activate deactivate 2 Use keys and followed by to select the single element 3 Use to activate the selected element or to deactivate it Other shortcuts...

Страница 22: ...ils For example the details of an Arm command will show the code and keypad concerned and if you press the list of partitions involved System voltage Zone status allows you to view only the zones asso...

Страница 23: ...icates Activate Output shortcut n 5 or Deactivate Output shortcut n 6 Via Wireless keyfob Push the respective button on the keyfob and verify the outcome of the requested operation as described in par...

Страница 24: ...Keypad Settings section of the User Menu by means of a valid PIN Follow the instructions described in Method 1 4 8 Change PIN This section allows you to change your User Code PIN If your code has Main...

Страница 25: ...hortcut n 7 Method 2 Access the Overtime req section of the User Menu by means of a valid PIN Via Reader Hold a valid digital key in the vicinity of the reader and select the LED or description relati...

Страница 26: ...nnot generate alarms The system generates tamper alarms even when partitions are disarmed ARM DISARM You can enable disable the Auto arm function on each separate partition If the auto arm option is e...

Страница 27: ...example after opening the front door otherwise the system will generate an alarm Each partition can be programmed with its own Exit time EXIT TIME OR EXIT DELAY These boards can be used to increase th...

Страница 28: ...the perimeter zones of the partition can generate alarms Instant mode this operation enables the partition perimeter zones only and annuls delays In this way violation of the perimeter zones of the p...

Страница 29: ...al entity for automatic time management of programmed peripherals or elements Ability control panels provide 2 timers TIMER Transceiver equipped devices In two way wireless systems all the devices are...

Страница 30: ...enu Accesses the User Menu section View 13 Keypad sett menu Accesses the User Menu section Keypad Keypad 14 ZoneBypass menu Accesses the User Menu section Activations Zones 15 Output control Accesses...

Страница 31: ...nel Backup battery low or disconnected Low battery The control panel backup battery is running low or is not connected properly Mains failure Mains failure The primary power source 230 Vac has failed...

Страница 32: ......

Отзывы: