BAL.0014 • 2019-01-16
EN - 17
WH / WHPP
6 Putting into operation
ABICOR BINZEL control board option for resistance adjustment
For this connection version, the control board and the micro-fuse are installed in the wire feed
unit at a readily accessible location. The required supply voltage is tapped, for example, at the
solenoid valve connection "Shielding gas ON/OFF" or at the "Control contactor". In some
cases, a series resistance for limiting the motor current is required.
Pull motor activation option
This connection version allows for a power supply of its own. The following operating options
are possible:
• Wire feed (welding)
• Wire feed (currentless)
• Wire return
These three functions are activated via robot outputs on the input plug X10, while the pull motor
is connected via the plug X11. For further information, such as connecting diagrams and
specifications, please refer to the operating instructions Pull Motor Activation.
1
Motor control
2
Push motor
3
Feed block
4
Feed rollers
5
Micro-fuse
6
Pull motor
7
Pull gearbox
8
Wire feed roller
9
Control board
For other voltages, a series
transformer is required!
10
Series resistance
Fig. 14
Control board option for resistance adjustment
M
1
2
3
4
9
M
6
7
8
5
R
R
10
1
Motor control
2
Push motor
3
Feed block
4
Feed rollers
5
Micro-fuse
6
Pull motor
7
Pull gearbox
8
Wire feed roller
9
Pull motor activation
Fig. 15
Pull motor activation option
M
1
2
3
4
11
X11 X10
M
6
7
8