BAL.0014 • 2019-01-16
EN - 21
WH / WHPP
9 Maintenance and cleaning
1
Remove adhering welding spatter.
2
Check all screw joints for tight fit.
BINZEL
offers repair services at the factory.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
NOTICE
• The maintenance intervals given are standard values and refer to single-shift operation.
• Check coolant hoses, seals, and connections for damage and tightness. Replace as
necessary.
• Always wear your personal protective equipment when performing maintenance and
cleaning work.