EN - 26
BAL.0014 • 2019-01-16
11 Dismounting
WH / WHPP
11 Dismounting
Dismounting may only be carried out by specialized personnel. Please make sure that the
shutdown procedures are strictly observed, before the dismounting work begins. Ensure this also
for the components integrated into the welding system.
1
Disconnect the hose assembly from the wire feed.
2
Remove the parts to be disconnected (changeable body, CAT robot holder, torch neck).
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance, servicing,
assembly, disassembly and repair work:
• Switch off the power source.
• Close off the gas supply.
• Close off the coolant supply.
• Close off the compressed air supply.
• Disconnect the coolant supply and return hoses.
• Disconnect all electrical connections.
NOTICE
• Consult the documentation for the welding components.
• Please take note of the following instructions: