BAL.0140 • 2018-10-15
EN - 9
PP Plus 36D/240D/401D
4 Putting into operation
7
Screw down nut
and secure with multiple wrench
.
4.3.2 PA liner
For use with aluminium, copper, nickel and stainless steels
1
Sharpen the beginning of the PA liner
to approx. 40° with the
ABICOR BINZEL
sharpener.
2
Slide PA liner
through the wire conduit
until a noticeable
resistance is felt.
3
Slide clamp nipple
, O-ring
on the PA-liner
and tighten the nut
under tension.
4
that is too long in front of the wire feed rolls.
NOTICE
• Mount the liner
pressing it slightly.
NOTICE
• New and unused liners must be abridged to the actual length of the cable assembly.
• For PA liners with an outer diameter of 4.00 mm, the capillary tube in the distance
adaptor must be replaced with a guide tube.
• We recommend that you sharpen the PA liner to an angle of 40° before assembly using
the
ABICOR BINZEL
sharpener.
1
Wire conduit
2
Central plug
3
Nut
4
Wire feed unit
5
ABICOR BINZEL
Cutter
6
Guide tube
7
O-ring
8
Clamp nipple
9
PA liner
10 ABICOR BINZEL
Sharpener
11
Inlet nipple
Fig. 4
Shortening the PA liner
40°
1
2
3
4
5
6
7
8
9
10
11