EN - 12
BAL.0789.0 • 2020-03-02
7 Operation
DAV
7 Operation
8 Decommissioning
Fig. 7
Flow chart
Yes
No
Yes
No
No
Yes
No
Yes
No
Yes
No
Yes
Cut wire
With option: end position prompt
Depends on the
wire length to be
advanced and
the speed
Function:
Cutter closed
* With function:
Pull wire, extend
waiting period
Function:
Cutter open
Currentless wire
feeder
Valve
Y1 = 1
Approach
position
Wait t = 0.5s *
Valve
Y1 = 0
Withdraw from
cutter
END
Cutter
open?
Cutter
closed?
Wait t = 0.5s *
Currentless wire
feeder
Cutter
open?
Cutter
closed?
Cutter
open?
Wait t = 0.5s *
Valve
Y1 = 0
Determine cause and rectify
Cutter
open?
NOTICE
• Only qualified personnel are permitted to perform work on the device or system.
• Consult the documentation for the welding components.
NOTICE
• As the DAV wire cutter is integrated into a welding system, the process for putting it out of operation depends on the
robot control system.
• Make sure that the shutdown procedures for all components integrated in the welding system are strictly observed.