6 Commissioning
DAV
6.3 Establishing the electrical connection (optional)
A digital robot output of 24 V DC at max. > 1.1 A or a comparable switch contact is required for controlling the valves.
4 Scope of delivery on page EN-7
A recovery diode D1 (1N4007) is required for the switching of inductive loads. We recommend the coupling socket at the
solenoid valve as the installation site. With option: non-contact end position prompt.
WARNING
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
NOTICE
• Before an electrical connection between the product and the power supply is established, check that the operating
voltage specified on the nameplate matches the actual voltage.
Fig. 5
Establishing the electrical connection
With option:
Non-contact end position
prompt