DAV
6 Commissioning
BAL.0789.0 • 2020-03-02
EN - 9
6 Commissioning
6.1 Installation
Install the DAV on a torch cleaning station, welding device or an ATS rotor.
1
Use screws to fix the DAV to a vibration-free surface.
2
Adjust the mounting bracket. To facilitate optimal accessibility and installation, the mounting bracket can be fixed to the
cylinder in four positions, each shifted by 90°.
6.2 Connecting the pneumatic system
The operating pressure equals a minimum of 6 bar to a maximum of 8 bar. The cutting capacity of the device is reduced if
the operating pressure is low.
4 Scope of delivery on page EN-7
DANGER
Risk of injury due to unexpected start
The following instructions must be adhered to during all maintenance, servicing, assembly, disassembly and repair work:
• Switch off the power source.
• Disconnect all electrical connections.
• Switch off the entire welding system.
NOTICE
• Only qualified personnel are permitted to perform work on the device or system.
NOTICE
• Use only cleaned and lubricated compressed air for the DAV.
Fig. 4
Connecting the pneumatic system
Cutter open/closed