EN - 8
BAL.0789.0 • 2020-03-02
5 Functional description
DAV
4.1 Transport
Although the items delivered are carefully checked and packaged, it is not possible to fully rule out the risk of transport
damage.
4.2 Storage
Physical storage conditions in a closed environment:
Tab. 2 Ambient conditions for transport and storage on page EN-6
5 Functional description
The housing
is attached to the actuating side of the cylinder
. The housing
consists of the slide
with the cutter
and the counter support
. When the wire cutter is activated, the cylinder
pushes the slide
support
then clamps the free wire end with spring force at the fixed jaws
on the slide
extends the
full cylinder stroke and cuts the wire. The position of the pneumatic cylinder is monitored by the optional end position
prompt
and torch clamp
. At a minimum of 5 bar operating pressure, the cylinder
is set in pneumatic end positions.
Signal evaluation is managed by a higher-level safety circuit.
Goods-in inspection
Use the delivery note to check that everything has been delivered.
Check the delivery for damage (visual inspection).
In case of complaints
If the delivery has been damaged during transport, contact the last carrier immediately.
Retain the packaging for potential inspection by the carrier.
Packaging for returns
Where possible, use the original packaging and the original packaging material. If you have
questions concerning packaging and safety during shipment, please consult your supplier,
carrier or transporter.
Tab. 8
Transport
1
Optional torch clamp
2
Cover
3
Counter support with pressure spring
4
Jaws
5
Housing
6
Cutter
7
Slide
8
Optional end position prompt with LED display
9
Cylinder
10
Mounting bracket
Fig. 3
Functional description
AF 4
1 Nm
AF 2.5
3
4
5
6
7
8
9
10
1
2