2 Installation
XSeriesG4 Remote Controller User's
manual
2103334 Rev. AB
| 27
Figure 26: Typical pipe saddle installation
2) Temporarily attach the saddle on the meter run pipe using the U-bolt and associated hardware; do not tighten.
3) Screw the
2” mounting pipe into saddle. Place level against pipe and vertically align. Adjust the pipe, mounted in
saddle, until vertical alignment is achieved.
4)
After vertical alignment, securely tighten 2” pipe in saddle and then securely tighten saddle mounting bolts. Be certain
pipe is securely installed in saddle.
NOTE:
To install the XRC
G4
, it is recommended that two people perform the installation: One to hold the unit in
position and the other to install and tighten the mounting brackets.
The method of
installation must be consistent with customer’s company policy.
Position the XRC
G4
on the 2” mounting pipe and secure in place with two U-bolts, flat washers, lock washers and two
5) Figure 27: XRC
G4
pipe mounting.
See Figure 28 through Figure 30 for final installation dimensions.
Figure 27: XRC
G4
pipe-mounting
2" x 40"
Mounting Pipe
Meter Run
"U" Mounting
Bolt
Saddle
Flat and lock washers
2 " Mounting Pipe
U - Bolt
with nut