![ABB UNO-DM-6.0-TL-PLUS Скачать руководство пользователя страница 59](http://html.mh-extra.com/html/abb/uno-dm-6-0-tl-plus/uno-dm-6-0-tl-plus_product-manual_4202059.webp)
- 59 -
000776AG
5 - Installation
I
ndependent channel configuration (default configuration)
This configuration is set at the factory and involves the use of the two
input channels (MPPT) in an independent mode. This means that the
jumpers (supplied) between the positive and negative poles of the two
DC input channels
12
must not be installed, and that the independent
channel mode should be set during the commissioning phase, in the de-
dicated section of the internal webserver “
SETTINGS > SETUP DC SIDE
> INPUT MODE
” or through the inverter display menu “
SETTINGS> IN-
PUT MODE
”.
P
arallel channel configuration
This configuration involves the use of the two input channels (MPPT)
connected in parallel. This means that the jumpers (supplied) between
the positive and negative poles of the two DC input channels
12
must
be installed, and that the parallel channel mode should be set during the
commissioning phase, in the dedicated section of the internal webserver
“
SETTINGS > SETUP DC SIDE > INPUT MODE
” or through the inverter
display menu “
SETTINGS > INPUT MODE
”.
DC INPUTS
-IN1 -IN1 +IN1 +IN1
+IN2 +IN2
-IN2 -IN2
12