![ABB UNO-DM-6.0-TL-PLUS Скачать руководство пользователя страница 105](http://html.mh-extra.com/html/abb/uno-dm-6-0-tl-plus/uno-dm-6-0-tl-plus_product-manual_4202105.webp)
- 105 -
000698BG
7 - Operation
Connection to the inverter in “AP Mode”
If the inverter wasn’t connected to the domestic wireless network, follow
this procedures:
• Enable the wireless connection on the device which is being used for
the board setup (tablet, smartphone or PC) and connect it to the Access
Point created by the inverter system: the name of the wireless network
created by the system that the connection should be established with,
will be:
ABB-XX-XX-XX-XX-XX-XX
where “
X
” is a hex digit of the wireless MAC address (MAC address can
be found on the “Wireless Identification Label” placed on the side of the
inverter or applied during the commissioning phase to the quick installa-
tion guide on cover page).
• When required digit the network password
ABBSOLAR
After 24 hours which the inverter is power-on, the access point default password “ABBSO
-
LAR” will be disabled and any subsequent access to the internal webserver will be possible
only using the PRODUCT KEY (printed on the “Wireless identification label” and applied du
-
ring the commissioning phase to the quick installation guide on cover page) as access point
password.
• Open an internet browser (reccomended browser: Chrome versions
from v.55, Firefox versions from v.50) and enter the pre-set IP address
192.168.117.1
to access the login page.