![ABB Triguard SC300E Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/abb/triguard-sc300e/triguard-sc300e_safety-manual_2874056.webp)
Issue 5 - September 2006
Page 56 of 65
11.2 MHB44IND 4 channels pulse input and 4 channel analogue output module.
The Piano module may only be used with TriBuild for Windows version 1.42 and RTTS 8.3-006
or above with the following restrictions.
1. The registers used for the analogue outputs must be initialised to 256 or greater to prevent
the module losing health.
2. The ladders for the analogue outputs must be configured to prevent the output registers
going below 256 resulting in the module losing health.
11.3 MAO04IND 4 channel analogue output module.
The following conditions must be applied when using the analogue output module
1. The registers used for the analogue outputs must be initialised to 256 or greater to prevent
the module losing health.
2. The ladders for the analogue outputs must be configured to prevent the output registers
going below 256 resulting in the module losing health.
11.4 System identification
Both RTTS 8.30 versions are identified by the title in the history report and by the
check sums of the EPROM’s as follows:
11.4.1 SC300E RTTS 8.30-005
Version 8.30 LOC SC-300E ROM System-005 Generated 19-May-2000 11:07
U86 -
486Eh
U106 -
0BC0h
U87 -
46ACh
U107 -
3E43h
11.4.2 SC300E RTTS 8.30-006
Version 8.30 LOC SC-300E ROM System-006 Generated 12-Jul-2000 15:38
U86 -
4885h
U106 -
0BCFh
U87 -
469Fh
U107 -
3D53h