16
Error Code 0030
1. Click
the
More Items
tab (see Figure 17). In this area, the user can
view all of the information that concerns this particular LevelMaster.
As the description and corresponding values are here, locate
Gain
Setting
and double-click on it.
Figure 17. Additional Setup Items
2. When the dialog box displays, if this setting needs to be changed,
click the drop-down arrow, and select the desired setting. Upon
selection, click
Send New Value
.
Testing the Sensor
The following information will take the user through the process of testing
the LevelMaster sensor.
1. Remove the Killark conduit dome cover on the top of the
LevelMaster sensor, and disconnect the green phoenix connector.
2. Remove the yellow fiberglass tension support and then lift the
interface board out of the conduit housing.
3. Disconnect the ribbon cable.
4. Connect the sensor ribbon cable to the test box cable.