3.11 Options
3.11.1 Fiscal metering system
The EVSE can optionally be equipped with a DC energy meter.
The dedicated Meter display
(10)
on the front panel shows:
A. Time (hh:mm:ss)
B. Date (YY-MM-DD)
C. Delivered DC power (kWh)
hh:mm:dd
YY-MM-DD
XXXX kWh
A
10
B
C
NOTE
The presence of the DC meter is mandatory in some countries. Do a check of the regulations
that are applicable in the region of installation.
3.11.2 Tilt sensors
The tilt sensor device
(37)
, and dedicated screw terminal blocks
(39)
for connection, is an optional that disables
the power from the incoming AC source when a tilt sensor detects a tilt of a cabinet of the EVSE in any direction.
37
39
The tilt sensor is generally closed and opens when the tilt exceeds 10° in any direction, for example if a vehicle
impacts against the EVSE. In these situations, the undervoltage release in the branch circuit breaker that
supplies power to the EVSE is de-energized and the branch circuit breaker opens.