6.7 Change the channel configuration

1. At the

System Configuration

page, press the

Channels

icon

to display the

I/O Groups 1(6) Channels

page.

2. Press the icon associated with the required

Group 1 (6)

Channels

(for example

) to display the

Channel 1 (01

…06)

dialog.

3. Press the

tab and then the

icon

associated with each field to enter and configure

Setup

parameters – press

to accept the content at each

field.

4. Repeat for all other tabs on the

Channel 1.01 (1.06)

dialog

and for all other required channels.

When all fields have been configured, press

to return

to the

I/O Groups 1(6) Channels

page then

to return

to the

System Configuration

page.

5. Proceed to the next step (6.8) to set up the inputs /

outputs (I/O).

6.8 Set up the inputs / outputs (I/O)

1. At the

System Configuration

page, press the

I/O

icon

to open an

I/O

page displaying fitted I/O modules.

2. Press the icon associated with the required module to

display the dialog and fields associated with that module.

3. Configure parameters for each required module.

4. When all parameters have been configured, press

to

return to the

I/O

page then

to return to the

System

Configuration

page.

5. Proceed to the next step (6.9) to exit

Configuration

level

and save changes.

6.9 Save current configuration and exit

1. Press

at the

System Configuration

page – a prompt

is displayed with options to

Apply Changes

,

Export

Configuration

,

Return to Configuration Mode

or

Discard

Changes

:

2. Press

Apply Changes

(

) to save the current

configuration and return to the

Operator

page.

3. Proceed to the next step (6.10) to start recording.

6.10 Start recording (archiving)

1. Open the media door and insert the external media card

and close the door.

Recording is initiated automatically.

Note.

Use the

arrows to select

different

Channels

in the same process group.

Note.

I/O modules are detected automatically.

Setup

Note.

Alternative archive media can be used –

refer to the Operating instructions (OI/RVG200-EN)
for compatible media types.

Apply Changes

Export Configuration

Return to Configuration Mode

Discard Changes

System Configuration

14

CI/RVG200–EN

Содержание ScreenMaster RVG200

Страница 1: ...values and fuse requirements 4 Navigation navigating the user interface quickly and effectively 5 Menus overview menu familiarization 6 Basic setup steps required for first time use 7 Symbols and ico...

Страница 2: ...sure to isolate the supply before removing the terminal cover Normal safety precautions must be taken to avoid the possibility of an accident occurring when operating in conditions of high pressure a...

Страница 3: ...rsonal injury and or death The user should reference this instruction manual for operation and or safety information This symbol when noted on a product enclosure or barrier indicates that a risk of e...

Страница 4: ...lectrical and magnetic fields If this is not possible particularly in applications where mobile communications equipment is expected to be used screened cables within flexible earthed metal conduit mu...

Страница 5: ...e terminals accept cables from 0 8 to 2 5 mm2 18 to 14 AWG The recorder conforms to Installation Category II of IEC 61010 All connections to secondary circuits must have basic insulation After install...

Страница 6: ...e 2 neutral 3 ground or DC supply terminals 4 5 Fig 3 Accessing the recorder connection terminals Note Tighten terminal screws to a torque of 0 1 Nm 0 9 lbf in Fig 4 Power supply connections and fuse...

Страница 7: ...0 9 8 7 6 5 4 1 2 18 17 16 15 14 13 12 3 11 10 9 8 7 6 5 4 1 2 13 12 L N Tx Tx Tx Rx 3 11 10 9 8 7 6 5 4 1 2 18 17 16 15 14 13 12 Tx Rx 1 2 3 4 5 6 1 2 3 4 5 RJ45 USB Inputs 1 to 6 RTD R THC Volt free...

Страница 8: ...e 2 of 2 Display Operator menu icons page 1 of 2 Exit Operator menus return to previous view Exit display Display associated menus Access dialog Accept settings Fig 8 Navigating groups and views Swipe...

Страница 9: ...ed by pressing the icon associated with the required function Select Group Configuration Operator Message Logging Select View Historical Review Screen Interval Acknowledge Alarm Auto Group Scroll Stop...

Страница 10: ...ation based on the instrument s default configuration Configuration menu options comprise Common Groups Channels I O Functions Logic Editor Maths equations System Configuration Common Setup Number of...

Страница 11: ...nable Bar graph markers Menu enables Batch if option enabled Enable Batch Recording Start Stop Abort Operator Login Batch Number Field 1 3 Title Channels Setup Source ID Trace color Zone Filter type S...

Страница 12: ...mentation Master Modbus TCP Port Poll Rate Poll fail limit Response Timeout Client Authorization TCP TCP Client Access Authorized IP 1 6 Comms analog I P Comms analog I P Protocol Comms Digital I P Co...

Страница 13: ...ay the Group Configuration dialog Select the channel s to be assigned to each group When allocation is complete press to return to the Common Configuration level 6 4 Set up the archive files 1 Press t...

Страница 14: ...ssociated with that module 3 Configure parameters for each required module 4 When all parameters have been configured press to return to the I O page then to return to the System Configuration page 5...

Страница 15: ...ration change File deleted Archive media inserted Archive media removed Archive media offline Archive media online Archive media full System error reset archiving Daylight time or daylight saving star...

Страница 16: ...he contents of this document without prior notice With regard to purchase orders the agreed particulars shall prevail ABB does not accept any responsibility whatsoever for potential errors or possible...

Отзывы: