BUSCH-/ABB-SECURE@HOME
2CSM600727D0901
32/74
8.5
Operating method and change language
To change the operating method:
1.
Log in as a level 2 user.
2.
Use the arrow keys to select the Options icon and press
ok.
3.
Press 5 Operating Method
-
Exclude
i.
Select "Force Block" to exclude the option: when Force Block is
Excluded, the central unit performs the system activation function
without requesting further confirmation in the event of one or more
system faults.
ii.
Select Led Notice to exclude the yellow "Notifications" triangle and
consequent need to reset. If disabled, the LED will never switch on,
even if there are stored notifications, or notifications that still have
not been viewed by the user.
iii.
Select All to exclude both Force Block and LED.
iv.
Select None to keep the pre-defined settings.
WARNING!
Exclusion of the Force Block and exclusion of the LED do not comply
with the EN 50131-1 standard.
-
Language
: select the desired language
WARNING!
The language selection takes effect immediately or within a short
time required for loading. The only exception is when switching
from/to Italian, which causes the system to restart automatically.
Options
1 Display settings
2 Audio Settings
3 Change date and
time
4 Change PIN
5 Other
6 Favorite
Exclude:
none >
Language
<ITA >