BUSCH-/ABB-SECURE@HOME
2CSM600727D0901
29/74
8.2.3
Alarms
To adjust the central unit buzzer in the event of alarms, perform points 1 and 2 from the
previous paragraph and press Audio settings:
Type
3
Internal Alarm.
-
Tampering
; set
Yes if you want the control unit to emit a sound in the event of
tampering, set No if you don't, Enabled if you only wish the control unit buzzer to
sound when the system is armed
-
Technological
, i.e. any of the technological alarms that might be configured
(flooding, gas leak etc.), even with the anti-intrusion system deactivated.
WARNING!
The Tampering setting is not compliant with EN 50131-1
Zones filter:
allows you to select the zones to be taken into account in the event of an alarm
(only for intrusion alarms and sensor tempering alarms). Factory settings include all zones. If
the alarm occurs in an excluded zone, the internal siren will not be triggered.
Adjust Audio
1 Beep volume
2 Audio Feedback
3 buzzer
Set reactions
Manumission
Yes >
Safety Alarm
Yes >
Zone filter
Configurations