FlexPendant application file(s) on the FlexPendant unit, you need to manually reset the FlexPendant for
it to reload its assets.
To manually reset the FlexPendant you need to use the reset button on the FlexPendant's backside. (See
Operating Manual – IRC5 with FlexPendant, 3HAC16590)
Running Routine with Movement
RunRoutine Button control does not always work correct when a routine with movements is called. As a
workaround use instructions like StopMove, StorePath, RestorePath and StartMove to control the
movements of the robot. A Trap routine could be called with a normal button control and in the Trap the
above instructions can be used to control the movements of the robot.
PictureBox control as a Widget
If a Picture Box control is created as a widget from a Windows 8 operating system, the control is not
shown on the FlexPendant. The behavior is fine with any other operating system like Windows 7.
© Copyright 2021 ABB. All rights reserved.