Communication
76
Instance 0x02 (Assembly instance 103 parameters), Attributes
Note:
Input and Output attributes can also be accessed with
RETA-01 configuration parameters 19-26.
Configuration Object, Class 0x92
This object is used to set the Idle action in ABB Drives profile.
Most Ethernet/IP masters implement the Run/Idle header and this
class was created to be able to define the drive behaviour in Idle
mode. (RETA-01 version 2.05 onwards)
Services
Class Attributes
ID#
Attribute name
Dflt,Min,Max
Description
0x01 Input I/O parameter 1
0,0,32767
UINT16
0x02 Input I/O parameter 2
0,0,32767
UINT16
0x03 Input I/O parameter 3
0,0,32767
UINT16
0x04 Input I/O parameter 4
0,0,32767
UINT16
…
0x20 Input I/O parameter 32
0,0,32767
UINT16
Class services:
Get Attribute Single
Instance services:
Get Attribute Single
Set Attribute Single
#
Name
Services Description
Dflt,Min,Max Data type
0x01 Revision
Get
Revision 2
0x0002
UINT