Function name

Signal type

Signal name

Description

 

 

CVMMXN:I

Calculated current

magnitude of deadband

value

 

 

CVMMXN:P

Active power magnitude of

deadband value

 

 

CVMMXN:PF

Power factor magnitude of

deadband value

 

 

CVMMXN:Q

Reactive power magnitude

of deadband value

 

 

CVMMXN:S

Apparent power magnitude

of deadband value

 

 

CVMMXN:V

Calculated voltage

magnitude of deadband

value

 

Binary inputs

CVMMXN:ILAG

Current is lagging voltage

 

 

CVMMXN:ILEAD

Current is leading voltage

DNPFREC

Analog inputs

DNPFREC:ActSetGrp

Active setting group

 

 

DNPFREC:Ch1Ang

Prefault Angle

 

 

DNPFREC:Ch1FltAng

Fault Angle

 

 

DNPFREC:Ch1FltMag

Fault Magnitude

 

 

DNPFREC:Ch1Mag

Prefault Magnitude

 

 

DNPFREC:Ch2Ang

Prefault Angle

 

 

DNPFREC:Ch2FltAng

Fault Angle

 

 

DNPFREC:Ch2FltMag

Fault Magnitude

 

 

DNPFREC:Ch2Mag

Prefault Magnitude

 

 

DNPFREC:Ch3Ang

Prefault Angle

 

 

DNPFREC:Ch3FltAng

Fault Angle

 

 

DNPFREC:Ch3FltMag

Fault Magnitude

 

 

DNPFREC:Ch3Mag

Prefault Magnitude

 

 

DNPFREC:Ch4Ang

Prefault Angle

 

 

DNPFREC:Ch4FltAng

Fault Angle

 

 

DNPFREC:Ch4FltMag

Fault Magnitude

 

 

DNPFREC:Ch4Mag

Prefault Magnitude

 

 

DNPFREC:Ch5Ang

Prefault Angle

 

 

DNPFREC:Ch5FltAng

Fault Angle

 

 

DNPFREC:Ch5FltMag

Fault Magnitude

 

 

DNPFREC:Ch5Mag

Prefault Magnitude

 

 

DNPFREC:Ch6Ang

Prefault Angle

 

 

DNPFREC:Ch6FltAng

Fault Angle

 

 

DNPFREC:Ch6FltMag

Fault Magnitude

 

 

DNPFREC:Ch6Mag

Prefault Magnitude

 

 

DNPFREC:Ch7Ang

Prefault Angle

Table continues on next page

Section 2

1MRK 511 244-UUS A

DNP3 data mappings

20

DNP, 650 series

Point list manual

© Copyright 2011 ABB. All rights reserved

Содержание RELION 650 SERIES

Страница 1: ...Relion 650 SERIES DNP 650 series Version 1 1 ANSI Point list manual...

Страница 2: ......

Страница 3: ...Document ID 1MRK 511 244 UUS Issued November 2019 Revision A Product version 1 1 Copyright 2011 ABB All rights reserved...

Страница 4: ...ed or disclosed only in accordance with the terms of such license Trademarks ABB and Relion are registered trademarks of ABB Group All other brand or product names mentioned in this document may be tr...

Страница 5: ...roduct failure would create a risk for harm to property or persons including but not limited to personal injuries or death shall be the sole responsibility of the person or entity applying the equipme...

Страница 6: ...cerning electrical equipment for use within specified voltage limits Low voltage directive 2006 95 EC This conformity is the result of tests conducted by ABB in accordance with the product standards E...

Страница 7: ...nventions 7 1 4 1 Safety indication symbols 7 1 4 2 Manual conventions 7 1 4 3 Functions included in 650 series IEDs 8 Section 2 DNP3 data mappings 15 2 1 Overview 15 2 2 Point list for the 650 series...

Страница 8: ...2...

Страница 9: ...48 4BEA 9E4F CC762FE28A3A v6 This manual addresses the communication system engineer or system integrator responsible for pre engineering and engineering for communication setup in a substation from a...

Страница 10: ...instructions on how to set up a PCM600 project and insert IEDs to the project structure The manual also recommends a sequence for engineering of protection and control functions LHMI functions as wel...

Страница 11: ...n protocol supported by the IED The manual concentrates on vendor specific implementations The point list manual describes the outlook and properties of the data points specific to the IED The manual...

Страница 12: ...034 UUS Commissioning manual 1MRK 502 035 UUS Product Guide 1MRK 502 036 BUS Type test certificate 1MRK 502 036 TUS Rotor Ground Fault Protection with Injection Unit RXTTE4 and REG670 1MRG001910 Docum...

Страница 13: ...pelled out in the glossary The glossary also contains definitions of important terms Push button navigation in the LHMI menu structure is presented by using the push button icons for example To naviga...

Страница 14: ...er swing detection ZCVPSOF Automatic switch onto fault logic voltage and current based ZGPDIS 21G Underimpedance protection for generators and transformers LEXPDIS 40 Loss of excitation OOSPPAM 78 Out...

Страница 15: ...PH 24 Overexcitation protection LOVPTUV 27 Loss of voltage check STEFPHIZ 64 100 Stator ground fault protection 3rd harmonic based Frequency protection SAPTUF 81 Underfrequency function SAPTOF 81 Over...

Страница 16: ...GIO IEC61850 generic communication I O functions double point SPC8GGIO Single point generic control 8 signals AUTOBITS AutomationBits command function for DNP3 0 I103CMD Function commands for IEC60870...

Страница 17: ...Function block for service value presentation of primary analog inputs 600TRM AM_P_P4 Function block for service value presentation of primary analog inputs 600AIM TM_S_P2 Function block for service v...

Страница 18: ...on protocol IED61870 5 103 IEC60870 5 103 serial communication via COM02 GOOSEINTLKRCV Horizontal communication via GOOSE for interlocking GOOSEBINRCV GOOSE binary receive GOOSEVCTRCONF GOOSE VCTR con...

Страница 19: ...me synchronization DTSBEGIN Time synchronization DTSEND Time synchronization TIMEZONE Time synchronization IRIG B Time synchronization SETGRPS Setting group handling ACTVGRP Parameter setting groups T...

Страница 20: ...14...

Страница 21: ...ties and configuration The point list table only shows the signals of the first instance of each function if more than one instance of a function can be configured See the engineering manual and DNP3...

Страница 22: ...input 9 COM_101 COM_CPI BI10 Binary input 10 COM_101 COM_CPI BI11 Binary input 11 COM_101 COM_CPI BI12 Binary input 12 COM_101 COM_CPI BI13 Binary input 13 COM_101 COM_CPI BI14 Binary input 14 COM_101...

Страница 23: ...O8_SO Binary output 8 signal output relay PSM_103 PSM03_CPI BO9_SO Binary output 9 signal output relay General command handling from DNP master In CMT the 1st binary command signal of instance 1 is sh...

Страница 24: ...neral functions for showing signals for DNP master In CMT the analog signal of instance 1 of MVGGIO is shown as MVGGIO 1 VALUE The signals can be connected to any binary respectively analog output sig...

Страница 25: ...gnal to CB CCSRDIF Binary inputs CCSRDIF FAIL Detection of current circuit failure CMMXU Analog inputs CMMXU I_A IA Amplitude CMMXU IA_ANGL A Angle CMMXU I_B IB Amplitude CMMXU IB_ANGL IB Angle CMMXU...

Страница 26: ...ult Magnitude DNPFREC Ch2Ang Prefault Angle DNPFREC Ch2FltAng Fault Angle DNPFREC Ch2FltMag Fault Magnitude DNPFREC Ch2Mag Prefault Magnitude DNPFREC Ch3Ang Prefault Angle DNPFREC Ch3FltAng Fault Angl...

Страница 27: ...Ch11Mag Prefault Magnitude DNPFREC Ch12Ang Prefault Angle DNPFREC Ch12FltAng Fault Angle DNPFREC Ch12FltMag Fault Magnitude DNPFREC Ch12Mag Prefault Magnitude DNPFREC Ch13Ang Prefault Angle DNPFREC C...

Страница 28: ...FREC Ch21FltMag Fault Magnitude DNPFREC Ch21Mag Prefault Magnitude DNPFREC Ch22Ang Prefault Angle DNPFREC Ch22FltAng Fault Angle DNPFREC Ch22FltMag Fault Magnitude DNPFREC Ch22Mag Prefault Magnitude D...

Страница 29: ...TrigMag Magnitude at trigger DNPFREC Ch33TrigMag Magnitude at trigger DNPFREC Ch34TrigMag Magnitude at trigger DNPFREC Ch35TrigMag Magnitude at trigger DNPFREC Ch36TrigMag Magnitude at trigger DNPFREC...

Страница 30: ...ommunication scheme logic ECRWPSCH Binary inputs ECRWPSCH CR POR Carrier signal received from remote end ECRWPSCH ECHO A signal that indicates channel pickup CS by WEI logic ECRWPSCH TRWEI Trip of WEI...

Страница 31: ...reverse direction FDPSPDIS REV_C Fault detected in phase phase C reverse direction FDPSPDIS REV_G Ground fault detected in reverse direction FDPSPDIS TRIP Trip by pilot communication scheme logic FMP...

Страница 32: ...up signal LEPDIS PU_C Fault detected in phase C LEXPDIS Binary inputs LEXPDIS TRIP Common trip signal LEXPDIS TRZ1 Trip signal from impedance zone Z1 LEXPDIS TRZ2 Trip signal from impedance zone Z2 LM...

Страница 33: ...Y LOC Local operation allowed QCBAY REM Remote operation allowed QCBAY UPD_BLKD Update of position is blocked REFPDIF Binary inputs REFPDIF BLK2H Block due to 2nd harmonic REFPDIF DIR_INT Directional...

Страница 34: ...N Analog inputs SESRSYN FRDIFFME Calculated difference in frequency SESRSYN PHDIFFME Calculated difference of phase angle SESRSYN VDIFFME Calculated difference in voltage Binary inputs SESRSYN AUTOENO...

Страница 35: ...COUNT3P4 Counting the number of three phase reclosing shot 4 SMBRREC COUNT3P5 Counting the number of three phase reclosing shot 5 SMPPTRC Binary inputs SMPPTRC CLLKOUT Circuit breaker lockout output...

Страница 36: ...ove alarm level SSIML TEMP_LO Temperature above lockout level STBPTOC Binary inputs STBPTOC TRIP General trip signal STBRREC Counters STBRREC 1PT1 Single phase reclosing in progress shot 1 STBRREC 3PT...

Страница 37: ...BLKD Update of position indication is blocked Counters SXCBR CNT_VAL Operation counter value Double bit indications SXCBR POSITION Apparatus position indication SXCBR TR_POS Truck position indication...

Страница 38: ...e sequence differential protection TCMYLTC Analog inputs TCMYLTC TCPOS Integer value corresponding to actual tap position Binary inputs TCMYLTC CNT_VAL Number of operations on tap changer TCMYLTC HIPO...

Страница 39: ...nputs TRPTTR ALARM1 First level alarm signal TRPTTR ALARM2 Second level alarm signal TRPTTR TRIP Trip Signal UC2PTUC Binary inputs UC2PTUC TRIP Common trip signal UC2PTUC TRST1 Trip signal for step 1...

Страница 40: ...gnal from voltage restraint overcurrent stage VR2PVOC TROC2 Trip signal from overcurrent function OC2 VSGGIO Binary inputs VSGGIO POS1 Position 1 indication logical signal VSGGIO POS2 Position 2 indic...

Страница 41: ...CWSPSCH TRWEI_C Trip of WEI logic in phase C ZGPDIS Binary inputs ZGPDIS TRIP Trip general ZGPDIS TRZ1 Trip zone 1 ZGPDIS TRZ2 Trip zone 2 ZGPDIS TRZ3 Trip zone 3 ZGPDIS TRZ4 Trip zone 4 ZGPDIS TRZ5 T...

Страница 42: ...36...

Страница 43: ...qualifiers 07 or 08 are responded with qualifiers 00 or 01 16 bit 32 bit and Floating point analog change events with time may be requested Floating point analog output status and output block object...

Страница 44: ...EvBufTout1 tUREvBufTout2 tUREvBufTout3 for each master session Unsolicited response retry delay configurable tURRetryDelay for each master session Unsolicited offline iInterval configurable tUROfflRtr...

Страница 45: ...solicited responses Sends static data in unsolicited responses Never Never Configurable UREnable on DNP3Master When device restarts Only certain objects When status flags change Sometimes attach expla...

Страница 46: ...ad 06 no range or all 07 08 limited qty 129 response 130 unsol resp 17 28 index 2 2 Binary input change with time 1 read 06 no range or all 07 08 limited qty 129 response 130 unsol resp 17 28 index 2...

Страница 47: ...7 28 index 20 5 32 bit binary counter without flag 1 read 00 01 start stop 06 no range or all 07 08 limited qty 17 27 28 index 129 response 00 01 start stop 17 28 index 20 6 16 bit binary counter with...

Страница 48: ...08 limited qty 32 1 32 bit analog change event without time 1 read 06 no range or all 07 08 limited qty 129 response 130 unsol resp 17 28 index 32 2 16 bit analog change event without time 1 read 06 n...

Страница 49: ...1 Internal indications 1 read 00 01 start stop 129 response 00 01 start stop 2 write 3 00 start stop index 7 No object function code only 13 cold restart No object function code only 14 warm restart...

Страница 50: ...44...

Страница 51: ...itive Coupled Voltage Transformer Class C Protection Current Transformer class as per IEEE ANSI CMPPS Combined megapulses per second CMT Communication Management tool in PCM600 CO cycle Close open cyc...

Страница 52: ...ork EIA Electronic Industries Association EMC Electromagnetic compatibility EMF Electric Motive Force EMI Electromagnetic interference EnFP End fault protection EPA Enhanced performance architecture E...

Страница 53: ...ic device I GIS Intelligent gas insulated switchgear Instance When several occurrences of the same function are available in the IED they are referred to as instances of that function One instance of...

Страница 54: ...e apparent impedance to the fault applied to the balance point that is the set reach The relay sees the fault but perhaps it should not have seen it PCI Peripheral component interconnect a local data...

Страница 55: ...instead synchronize with a remote clock providing the required accuracy SRY Switch for CB ready condition ST Switch or push button to trip Starpoint Neutral Wye point of transformer or generator SVC...

Страница 56: ...conds to synchronize it with Universal Time 1 UT1 thus allowing for the eccentricity of the Earth s orbit the rotational axis tilt 23 5 degrees but still showing the Earth s irregular rotation on whic...

Страница 57: ...51...

Страница 58: ...ht 2011 ABB All rights reserved Scan this QR code to visit our website 1MRK 511 244 UUS ABB AB Substation Automation Products SE 721 59 V ster s Sweden Phone 46 0 21 32 50 00 www abb com substationaut...

Отзывы: