CoE Error codes
73
CoE Error codes
What this chapter contains
This chapter contains a list of the CANopen over EtherCAT® error
codes.
Error codes
Error codes can be read from the objects 0×200B and 0×603F
(hex). Additionally, when the error occurs, an EMCY object
containing the code is transmitted to the master. The module
signals a cleared error (i.e. reset drive fault) with an EMCY object
containing the error code 0x0000 (hex) "Error reset or no error".
The CoE error codes are described in following table
CoE error
codes
.
Error codes between xx80…xxFF (hex) and between
FF00…FFFF (hex) are manufacturer specific. Descriptions for
these error codes can be found in the appropriate drive firmware
manual and/or the drive fault code parameter.
CoE error codes
Error
code (hex)
Meaning
0000
Error reset or no error
1000
Generic error
2000
Current
2100
Current on device input side
2110
Short circuit / earth leakage
2120
Earth leakage
2121
Earth leakage phase L1
2122
Earth leakage phase L2
2123
Earth leakage phase L3
2130
Short circuit
Содержание RECA-01
Страница 1: ...ABB Drives User s Manual EtherCAT Adapter Module RECA 01 ...
Страница 2: ...EtherCAT is registered trademark and patented technology licensed by Beckhoff Automation GmbH Germany ...
Страница 4: ......
Страница 6: ...Safety instructions 6 ...
Страница 24: ...Quick start up guide 24 ...
Страница 26: ...Mechanical installation 26 ...
Страница 28: ...Electrical installation 28 ...
Страница 32: ...Master configuration 32 ...
Страница 56: ...Communication 56 ...
Страница 72: ...CoE object dictionary 72 ...
Страница 80: ...CoE Error codes 80 ...
Страница 82: ...Definitions and abbreviations 82 ...