Note
Action
xx2300001097
Refit the synchronization plate axis-6.
10
Connecting the axis-6 motor cables
Note
Action
Connect the motor cables.
1
Connect in accordance with the markings
on the connectors.
Tightening torque: 1 Nm
Position the power connector to the bracket
with a screw.
Note
The purpose of the screw is to secure the
mating of the connectors and the position-
ing of the connector in the connection box.
It is normal that the connector can be
moved back and forth after the screw has
been tightened according to the torque
specification and, in some connection
boxes, that the screw is not even fully inser-
ted when it bottoms.
2
xx2200001731
xx2200001921
Snap the signal connectors to each other
in the bracket.
3
Continues on next page
604
Product manual - IRB 6740
3HAC085701-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.9.4 Replacing the axis-6 gearbox
Continued