Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safe-
guarded space.
2
Make sure that the oil temperature is +25°C
± 10°C.
3
WARNING
Handling gearbox oil involves several
safety risks, see
4
xx2100002077
Open the oil plug.
5
Check the oil level.
6
Required oil level is:
IRB 6740-310/2.8, IRB 6740-260/3.0, IRB
6740-270/2.8 LID, IRB 6740-230/3.0 LID:
75-80 mm below oil plug hole
IRB 6740-240/3.2, IRB 6740-220/3.2 LID:
51-58 mm below oil plug hole
Type of oil and total amount is detailed in
Technical reference manual - Lubrication
in gearboxes
.
Add or drain oil, if required.
7
Further information about how to drain or
fill with oil is found in section
oil in axis-6 gearbox on page 162
Continues on next page
Product manual - IRB 6740
133
3HAC085701-001 Revision: A
© Copyright 2023 ABB. All rights reserved.