Preparations before removing the gearbox
Note
Action
Decide which calibration routine to use, and take
actions accordingly prior to beginning the repair
procedure.
1
xx2300000677
Jog the robot into position:
•
Axis 1: 0°
•
Axis 2: -60°
•
Axis 3: +65° (approximately)
•
Axis 4: 0°
•
Axis 5: +90°
•
Axis 6: +90° (if DressPack is installed)
CAUTION
Check that the balancing device ear does not
collide with the ear on the lower arm when jogging
the axis-2 into position.
2
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safeguarded
space.
3
See
Draining the axis-2 gearbox on
Begin draining the gearbox.
4
Attaching lifting accessories to the lower and upper arm
Note
Action
CAUTION
The weight of the complete upper and lower arm
together is 535-565 kg (depending on robot vari-
ant)
All lifting accessories used must be sized accord-
ingly.
1
Lifting eye: 3HAC16131-1
Fit a lifting eye to the wrist.
2
xx2200001522
Continues on next page
514
Product manual - IRB 6740
3HAC085701-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.9.2 Replacing the axis-2 gearbox
Continued
Содержание OmniCore IRB 6740
Страница 1: ...ROBOTICS Product manual IRB 6740 ...
Страница 8: ...This page is intentionally left blank ...
Страница 14: ...This page is intentionally left blank ...
Страница 36: ...This page is intentionally left blank ...
Страница 176: ...This page is intentionally left blank ...
Страница 608: ...This page is intentionally left blank ...
Страница 638: ...This page is intentionally left blank ...
Страница 658: ...This page is intentionally left blank ...
Страница 663: ......