Start-up
Counter
The encoder pulses can be used as the signal source for the
counter. For more information on the counter function, refer to
chapter Program features in
ACS350 User’s Manual
[3AFE68462401 (English)].
Index Name/
Selection
Description
Default
FbEq
1)
19 TIMER &
COUNTER
1906 COUNTER
INPUT
Selects the input signal source for the counter. PLS IN(DI 5)
PLS IN(DI 5)
Digital input DI5 pulses. When a pulse is
detected, the counter value increases by 1.
1
ENC W/O DIR
Encoder pulse edges. When a rising or a
falling edge is detected, the counter value
increases by 1.
2
ENC WITH DIR Encoder pulse edges. The direction of rotation
is taken into account. When a rising or falling
edge is detected and the direction of rotation
is forward, the counter value increases by 1.
When the direction of rotation is reverse, the
counter value decreases by 1.
3
1)
Fieldbus equivalent, scaling between the value and the integer used in serial communication.