2 Installation and commissioning
2.5.7. Fitting cable package attachments (Cleanroom)
3HAC026876-001 Revision: C
72
© Copyri
ght
200
6-2008 ABB.
All rights reserved.
Fitting of cable package attachments - lower end
The procedure below details how to install the attachments at the lower end of the cable
harness (Cleanroom).
Other tools and
procedures may be
required. See references
to these procedures in the
step-by-step instructions
below.
These procedures include
references to the tools required.
Equipment
Part no.
Note
Action
Note
1.
DANGER!
Turn off all electric power, hydraulic and pneumatic
pressure supplies to the robot!
For Foundry Prime robots: Do not turn off the air
pressure to motors and SMB.
2. Fit the shelf to the frame with its attachment screws.
Lock screws with locking liquid.
Locking liquid is specified in
xx0800000006
Parts:
•
A: Shelf
•
B: Attachment screws
M10x16 quality 8.8-A3F (3
pcs)
Continued
Continues on next page