Note
Action
xx2100002186
Lower the motor into position.
•
Make sure that the motor pinion is properly
mated to the gear in the gearbox.
•
Make sure that the motor pinion does not
get damaged.
•
Make sure that the direction of the cable
gland exit is facing the correct way.
6
Hex socket head cap screw:
M10x30 12.9 Gleitmo 603+Geomet
500 (4 pcs)
Secure the motor with its attachment screws and
washers.
Use a bits extender to reach the screws.
7
Bits extender: 3HAC12342-1
Tightening torque: 50 Nm.
xx2100000503
Disconnect the brake release tool.
8
See
.
Perform a leak-down test (if not already done).
9