Note
Action
Secure the battery cable with cable straps.
7
A
B
C
xx0800000456
Use caution when pushing the
base cover
into position while at the same time check-
ing that no cables are damaged.
8
Parts:
•
A: Attachment screws (6 pcs)
•
B: Base cover
•
C: Base
Refit the
base cover
.
9
Calibration is detailed in a separate calib-
ration manual enclosed with the calibra-
tion tools.
Recalibrate the robot.
10
General calibration information is included
in section
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further detailed in the section
- First test run may cause injury or damage!
on page 50
.
11
3HAC033453-001 Revision: H
227
© Copyright 2009-2013 ABB. All rights reserved.
4 Repair
4.3.3 Replacing SMB unit
Continued