Interval
Equipment
Maintenance activity
First change when DTC
reads:
•
6,000 hours
Second change when DTC
reads:
•
24,000 hours
Following changes:
•
Every 24,000 hours.
Oil in axis-3 gearbox
Change
No change needed.
Oil in axis-4 gearbox
Change
First change when DTC
reads:
•
6,000 hours
Second change when DTC
reads:
•
24,000 hours
Following changes:
•
Every 24,000 hours.
Oil in axis-5-6 gearbox
Change
Every:
•
40,000 hours .
Robot
Overhaul
36 months or battery low alert
iv
Battery pack, measurement
system of type RMU101 or
RMU102 (3-pole battery con-
tact)
Replacement
Battery low alert
v
Battery pack, measurement
system with 2-pole battery
contact, e.g. DSQC633A
Replacement
i
Replace when damage or cracks is detected or life limit is approaching that specified in section
Expected component life on page 113
ii
Check more often if the environment is very contaminated.
iii
DTC = Duty Time Counter. Shows the operational time of the robot.
iv The battery low alert (38213
Battery charge low
) is displayed when the battery needs to be replaced.
The recommendation to avoid an unsynchronized robot is to keep the power to the controller turned
on until the battery is to be replaced.
See the replacement instruction for more details.
v
The battery low alert (38213
Battery charge low
) is displayed when remaining backup capacity
(robot powered off) is less than 2 months. The typical lifetime of a new battery is 36 months if the
robot is powered off 2 days/week or 18 months if the robot is powered off 16 h/day. The lifetime
can be extended with a battery shutdown service routine. See
Operating manual - IRC5 with
FlexPendant
for instructions.
Activities and intervals, optional equipment
The table below specifies the required maintenance activities and intervals for
common optional equipment. The maintenance of other external equipment for the
robot is detailed in separate documentation.
Note
Interval
Equipment
Maintenance activity
Every:
Signal lamp
Inspection
12 months
Every:
Additional mechanical
stop, axis 1
Inspection
12 months
Inspect the fan for contam-
ination that could hinder
the air supply. Clean if ne-
cessary.
Every 12
months
Motor fan
Inspection
112
3HAC033453-001 Revision: H
© Copyright 2009-2013 ABB. All rights reserved.
3 Maintenance
3.2.2 Maintenance schedule
Continued
Содержание IRB 4600 - 20/2.50
Страница 1: ...ABB Robotics Product manual IRB 4600 ...
Страница 2: ...Trace back information Workspace R13 2 version a3 Checked in 2013 10 15 Skribenta version 4 0 378 ...
Страница 8: ...371 Index 8 3HAC033453 001 Revision H Copyright 2009 2013 ABB All rights reserved Table of contents ...
Страница 108: ...This page is intentionally left blank ...
Страница 318: ...This page is intentionally left blank ...
Страница 332: ...This page is intentionally left blank ...
Страница 373: ......