Note
Action
xx0900000100
Remove the screw that secures the bracket
and unscrew the three other screws a little
just enough to be able to slide the bracket
sideways.
Note
It is not needed to remove these three
screws.
4
Parts:
•
A: Screw to be removed
•
B: Screws to be unscrewed a little
(3 pcs)
Cable harness can stay connected to all
connectors except to the SMB unit.
xx0900000013
Remove the
bracket
by sliding it off the re-
maining three attachment screws and put
it at a 90° angle from the base.
Putting the bracket at a 90° angle facilitates
the disconnecting of cables from the
bracket.
Note
Use caution when performing this procedure
order not to damage cables or other com-
ponents!
5
Parts:
•
A: Bracket at a 90° angle
•
B: Base
A
xx0900000035
Disconnect cable clamps.
6
Parts:
•
A: Cable clamps
See the figure in:
•
Location of SMB unit on page 223
Unscrew the
attachment screws
securing
the SMB unit just enough to be able to re-
move the SMB unit.
7
Remove the SMB unit.
8
Continues on next page
3HAC033453-001 Revision: H
225
© Copyright 2009-2013 ABB. All rights reserved.
4 Repair
4.3.3 Replacing SMB unit
Continued
Содержание IRB 4600 - 20/2.50
Страница 1: ...ABB Robotics Product manual IRB 4600 ...
Страница 2: ...Trace back information Workspace R13 2 version a3 Checked in 2013 10 15 Skribenta version 4 0 378 ...
Страница 8: ...371 Index 8 3HAC033453 001 Revision H Copyright 2009 2013 ABB All rights reserved Table of contents ...
Страница 108: ...This page is intentionally left blank ...
Страница 318: ...This page is intentionally left blank ...
Страница 332: ...This page is intentionally left blank ...
Страница 373: ......