4.4.3 Replacement of damper, axis 5
Location of damper, axis 5
The damper, axis 5, is located as shown in the figure below!
xx0600002806
Damper, axis 5
A
Recess
B
Required equipment
Note
Spare part no.
Equipment, etc.
3HAB 8964-1
Damper, axis 5
Content is defined in section
.
Standard toolkit
CAUTION
Always cut the paint with a knife and grind the paint edge when disassembling
parts. See
Cut the paint or surface on the robot before replacing parts on page 118
.
Removal, damper axis 5
The procedure below details how to remove the damper, axis 5.
Note
Action
Shown in the figure
Run the robot to a position that enables the end of
the
damper
to be pushed into the
recess
in the wrist
unit.
1
Continues on next page