Parameter
Specification
Test voltage
4 kV
Ambient temperature range
-40 °C to +80 °C (-40 °F to +176 °F)
Strip length
20 mm (0.78 in)
12.13.5
DC power cables
Parameter
Specification
Type
1x positive, 1x negative cable
Unshielded
Number of cores
1
Cross section range (minimum)
95 mm² (3/0 AWG)
Cross section range (maximum)
185 mm² (350 MCM)
Diameter
22-32 mm (0.9-1.25 in)
Maximum length between the power
cabinet and the control box
100 m (330 ft)
Conductor
Stranded in tin plated copper or alumi-
num,fine wired, stranded according to VDE
0295 cl.5/IEC Cl.5
Diameter of the phase conductors
Refer to the local rules.
Insulation
Rubber or PVC that is serviceable for out-
door use, UV-protected, and oil resistant
Nominal voltage Uo/U
600/1000 Vac - 900/1500 Vdc
Minimum test voltage
6 kV
Ambient temperature range
-40 °C to +80 °C (-40 °F to +176 °F), permissi-
ble conductor operating tempe90 °C
(+194 °F)
Strip length
11 mm (0.4 in)
Note:
•
Calculate the cable cross-section to guarantee the voltage drop
below 10V. If the voltage drop is above 7V, consult the manufacturer.
•
If the length of the cables between the power cabinet and the control
box is between 328 and 492 ft, you need to install a long-distance
package. The long-distance package is included in a separate manual.
Ask the manufacturer.
12.13.6
DC auxiliary power cables
Parameter
Specification
Type
1x positive, 1x negative cable
Unshielded
Number of cores
2 wires
Core identification
Color Acc. to IEC 60446
Cross section
2.5-10 mm² (14-8 AWG)
Diameter
10-14mm (0.4-0.6 in)
Technical data